FMBR technology

 

FMBR Technology Introduction

 

FMBR technology is independently developed by JDL (China Patent No:ZL200910115352.0; US Patent No: US8173019B2; European Patent No:EP2253596; UK Patent No:GB2439647; Japan Patent No:JP5352528, etc.).  The main contribution of this technology is to find, apply and control special bacteria which can synchronously treat wastewater and sludge without foul odor. This innovative and leading technology is well recognized by the national authority.

 

FMBR Technology:

 

 

 

Traditional Treatment

 

Features

Innovative ——World’s leading technology, registered 36 domestic and foreign invention patents
Pragmatic —— The treatment of wastewater is practical and it is just like automatic camera
Safe and Clean ——No organic sludge, no secondary pollution and convenience to select a site
Economical ——The total cost is 50% lower than the traditional technology
 
Techno-economic comparison
 

Technology

The Stability of Water Quality

Organic Sludge

Treatment

Investment

(Unit:10000CNY)

Operation Cost

(CNY/ton)

Occupied Area ()

Artificial Wetland Ecosystem Treatment System

Unstable

(subject to climate change)

Relatively difficult

(Odor pollution)

~A

>1.5B

>600

Artificial Biological

Treatment System

Unstable

(subject to operating techniques)

Difficult

(Odor pollution)

~A

>3B

>100

FMBR

Stable

Easy (Environmentally friendly)

~A

~B

~20

Remark

Wastewater discharge standardsReclaimed water quality standards

 

Compensation for occupation of  land

0.03/

3000 per person per month

Major component of facility

Remark:Assume 100 don/day wastewater is treated

 

 

Product Performance

Input Water and Treated water Quality(Typical Domestic Sewage as an Example)
Project
pH
COD
(mg/L)
BOD5
(mg/L)
NH3-N
(mg/L)
Color Measure
(degree)
SS
(mg/L)
TP
(mg/L)
Input water quality
 
6~9
 
200~400
~200
~30
~80
~200
~3
Treated water  quality
6~9
≤ 25
≤ 5
≤ 8(15)
≤ 10
≤ 5
~0.5
 
 
 
 
 
 
 
 
 
 
The quality of the treated water accord with the national Standards: the reuse of urban recycling water – water quality standard for urban miscellaneous water consumption, GB/T 18920-2002,and other relevant national standards.

 

Model and Parameters

 
Specifications  (ton/day)
Population Coverage
(person)
W×L×H(m)  
Area (㎡)
Net Weight (ton)
Operation Weight   (ton)
Power(kw)
FMBR-15
~150
1.4×6.2×1.7
8.68
3.1
12.6
1.87
FMBR-50
~500
2.0×6.5×2.8
13.0
4.4
24.8
2.0
FMBR-100
~1000
2.0×9.1×2.8
19.0
5.5
33.5
2.8
FMBR-200
~2000
2.8×9.5×3.5
27.0
9.0
65.0
2.95
FMBR-300
~3000
2.8×12.3×3.5
35.0
12.5
85.0
5.2
FMBR-500
~5000
2.8×15.0×3.5
42.0
14.5
110
6.6